Document Type : Original Article
Authors
1 Msc graduated in Water structure, Sari Agricultural Sciences and Natural Resources University
2 Associate Professor, Sari University, Sari, Iran
3 Associate Professor, Sari Agricultural Sciences and Natural Resources University
Abstract
Labyrinth weirs are considered as appropriate option for correction of weirs facing problems with maximum conveyance flow rate. In this research, 5 rectangular labyrinth weirs with 4 different slopes in downstream and upstream ramps were investigated in laboratory condition. The experiments were carried out for 4 different ramp slopes, including: no slope, 15, 30 and 45 degrees. Our findings showed that, for rectangular labyrinth weir with upstream and downstream ramps slope, discharge coefficient decreased when Ht/P increased. It was also indicated that, in case of creation of slope in downstream and upstream ramps, the discharge coefficient of rectangular labyrinth weir increased and decreased, respectively compared to no slope condition. Furthermore, it was found that in rectangular labyrinth weir model, increase in weir's effective length resulted reduction in discharge coefficient, and that increase in weir's height caused increase in discharge coefficient. Finally, we presented equations of discharge coefficients based on effective dimensionless parameters.
Keywords
(in Persian)
(in Persian)
(in Persian)